Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Radiol Case Rep ; 18(12): 4485-4488, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37868009

RESUMO

A 78-year-old male had undergone endovascular aortic aneurysm repair (EVAR) 7 years prior to presentation. Although the sac was stable 6 months ago, the patient presented with shock at arrival, and CT showed aortic rupture with rapid expansion due to type Ib endoleak caused by iliac neck dilatation (IND). The aneurysm sac was excluded using an endovascular strategy. Bell-bottom iliac limbs can cause IND associated with type Ib endoleak. Additionally, the risk of rupture is high when re-expansion of an aneurysm occurs after sac regression after EVAR. Therefore, close follow-up is mandatory for patients with IND after EVAR.

2.
Ann Vasc Dis ; 16(2): 135-138, 2023 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-37359095

RESUMO

We report a case of recurrent internal iliac artery aneurysm previously treated with a combination of stent graft placement and coil embolization in an 85 year-old male patient. The patient was scheduled for the direct puncture embolization of the superior gluteal artery. The patient was placed in a prone position under general anesthesia. An 18G-PTC needle was inserted into the superior gluteal artery under ultrasonographic guidance. A 2.2F microcatheter was inserted through an outer needle and advanced to the aneurysmal sac. Coil embolization was successfully performed without endoleaks. This approach is technically feasible when other treatment options fail or are deemed unsuitable.

3.
Ann Thorac Cardiovasc Surg ; 29(5): 266-269, 2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-35342146

RESUMO

From April 2018 to February 2021, 150 patients underwent MitraClip implantation for severe functional mitral regurgitation (MR) at our hospital. Two of our patients, an 85-year-old man and an 84-year-old woman, developed a single leaflet device attachment in the acute phase after the implantation and had severe residual MR requiring surgical correction. The recurrent MR was first pointed out on day 5 and day 4, and the duration between MitraClip implantation and surgery was 13 and 55 days, respectively. Due to strong adhesions with the clips and severe valve damage after MitraClip implantation, both cases underwent mitral valve replacement with a good postoperative course. In patients with a high-risk baseline profile, surgical mitral valve replacement after failed MitraClip implantation should be considered at an optimal timing, and a detailed echocardiographic follow-up is required.

4.
Ann Thorac Cardiovasc Surg ; 29(3): 153-156, 2023 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-35082190

RESUMO

The patient was a 69-year-old man who underwent emergency surgery for acute aortic dissection that developed 5 months after coronary artery bypass grafting. The left internal thoracic artery (LITA) graft anastomosed to the left descending artery was not affected by the aortic dissection, and during the ascending aortic replacement, the artery was not identified for clamping. Although fully sufficient cardioplegia was not achieved due to the patent LITA graft, the patient's postoperative cardiac function was good. The two anastomotic sites of the vein grafts to the ascending aorta were excised along with a remnant of the aortic wall in an island fashion and were reimplanted onto the artificial graft. Based on the site of intimal tear, we speculated that partial clamping during the previous surgery had caused the dissection.


Assuntos
Dissecção Aórtica , Ponte de Artéria Coronária , Masculino , Humanos , Idoso , Resultado do Tratamento , Ponte de Artéria Coronária/efeitos adversos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Dissecção Aórtica/cirurgia , Aorta/cirurgia , Aorta Torácica/cirurgia
5.
Ann Vasc Dis ; 15(4): 308-316, 2022 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-36644254

RESUMO

Objectives: This study aims to discuss the midterm results of thoracic endovascular aortic repair (TEVAR) with reentry closure for chronic type B aortic dissection (CTBAD). Materials and Methods: This retrospective study analyzed 13 patients with CTBAD who underwent TEVAR with reentry closure between July 2014 and December 2020. We evaluated the false lumen (FL) cross-sectional area using computed tomography images of the descending aorta at the level of the bronchial bifurcation, Valsalva sinus, celiac artery, and infrarenal abdominal aorta pre- and postoperation. The study endpoints were technical and clinical success rates, freedom from additional aortic reintervention or surgery, and survival. Results: Technical success was obtained in 12 patients (92.3%) with no hospital mortality and neurological complications. The postoperative observation period was 49.2±21.5 months. The clinical success rate was 76.9% (10 cases), and a postoperative reduction of the FL cross-sectional area was obtained in 53.8% of patients. The 5-year overall survival rate was 64.8% with no aortic-related deaths while the 5-year freedom from additional aortic surgery rate was 66.7%. Conclusions: TEVAR with reentry closure suggests preventing FL dilatation or rupture in CTBAD, but the revision of our devices and further research with more patients and longer follow-up periods are required.

6.
Ann Vasc Dis ; 15(4): 341-343, 2022 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-36644269

RESUMO

Congenital abdominal aortic aneurysm (AAA) with coarctation has been considered an extremely rare condition. In this study, we present a 3-year-old boy, who was diagnosed by chance with congenital AAA at first operation. We replaced the AAA+coarctation with a 6-mm polytetrafluoroethylene (PTFE) graft. Histological examination of the aortic wall revealed no particular abnormalities. Collateral vessels were noted to develop over 14 years of followup. Good blood flow to both lower limbs and no intermittent claudication were observed. After growth, at the age 17, he underwent extra-anatomical bypass using a 12-mm PTFE graft. This is the first report of successful treatment of congenital AAA+coarctation with longterm followup.

7.
Ann Vasc Dis ; 14(2): 139-145, 2021 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-34239639

RESUMO

Objective: To describe the clinical utility and technical aspects of the candy-plug technique using an Excluder aortic extender (Ex-cuff) for false lumen (FL) occlusion in chronic aortic dissection. Materials and Methods: This is a retrospective study analyzing seven consecutive patients (mean age, 63 years; range, 44-78 years; 6 men) with aneurysmal dilatation or rupture in chronic aortic dissection. All patients had undergone thoracic endovascular aortic repair with FL occlusion using this technique. We assessed technical (deployment accuracy) and clinical (no FL backflow on the latest contrast-enhanced computed tomography) success. Results: Technical success was obtained in six patients (86%). Technical failure was caused by the malposition of the candy-plug. The mean follow-up period was 593 days (range, 222-1225 days). Clinical success was obtained in four (57%), and incomplete Amplatzer Vascular Plug (AVP) embolization was seen in two. There was no enlarged FL after the procedure, and all patients are alive during the follow-up periods. Conclusion: The candy-plug technique using an Ex-cuff may be a feasible option; however, it takes time to achieve complete AVP embolization. Therefore, using additional embolic materials should be considered when we use it for the rupture case. (This is a translation of Jpn J Endovasc Interv 2018; 19: 29-35.).

8.
Ann Vasc Dis ; 14(1): 75-78, 2021 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-33786106

RESUMO

A 66-year-old man presented with an enlarging abdominal aorta false lumen, after type A aortic dissection repair. Residual entries were located at the left renal artery, abdominal aorta, and left external iliac artery. The patient underwent endovascular aortic repair with left renal artery stenting to close the entries. Completion aortography showed no false lumen flow without an endoleak, and contrast-enhanced computed tomography 1 month after the procedure demonstrated complete false lumen thrombosis. A total endovascular approach is possible for abdominal aneurysmal dilation in chronic aortic dissection when all entries can be closed using a one-stage procedure with stent grafts and/or branch stenting.

10.
Ann Vasc Dis ; 13(1): 72-75, 2020 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-32273926

RESUMO

We report the case of a 83-year-old man with aneurysmal sac enlargement after endovascular aneurysm repair for an abdominal aortic aneurysm, despite no overt endoleak (EL) detected on imaging. Occult type II EL was suspected, and treatment was performed. However, the aneurysm continued to enlarge. Thus, we diagnose with type V EL as exclusion diagnosis. We combined an aortic cuff and stent-graft leg to cover the initially inserted stent graft, as a diagnostic treatment for unrefined type IIIb EL. Subsequently, the aneurysm diameter decreased. This technique and concept may be effective for type V EL, which may include another type occult EL.

11.
Ann Vasc Dis ; 13(3): 269-272, 2020 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-33384729

RESUMO

Objective: To evaluate the clinical utility of the coil in plug (CIP) method in internal iliac artery (IIA) embolization during endovascular aortic aneurysm repair (EVAR) compared to conventional coil embolization (CCE). Material and Methods: From July to December 2018, 10 patients who underwent IIA embolization during EVAR were divided into CIP (n=5) and CCE (n=5) groups. In the CIP technique, the AVP-1 with a size more than 30%-50% of that of the embolized IIA diameter was used. The AVP-1 was deployed in the IIA. Before detachment of the AVP-1, a 2.2-F micro catheter was inserted through the 6-F delivery guiding sheath, and entered the plug. The AVP-1 was then packed with hydrogel micro coils. We compared number of coils used, embolization length, embolization time, volume embolization ratio, and embolic material cost between the groups. Results: The CIP method achieved shorter embolization length with fewer coils used compared to CCE. The CIP method decreased the cost of total embolic materials. Conclusion: The CIP method can achieve shorter embolization length with fewer coils used compared to CCE.

12.
Ann Vasc Dis ; 13(4): 441-443, 2020 Dec 25.
Artigo em Inglês | MEDLINE | ID: mdl-33391567

RESUMO

This report describes a successful case of transcatheter arterial embolization for a critical vascular injury during lumbar disk surgery that resulted in a large retroperitoneal hematoma in a 72-year-old woman. A 4-Fr long sheath was inserted via the right popliteal artery in the prone position. Pelvic angiography revealed a pseudoaneurysm in the right internal iliac artery, which was managed with coil embolization. The patient underwent laparotomy because of abdominal compartment syndrome and was discharged in good condition after rehabilitation. The transpopliteal endovascular approach in the prone position may thus provide the best chance to treat this rare but critical condition.

13.
Gen Thorac Cardiovasc Surg ; 68(6): 557-564, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31617148

RESUMO

OBJECTIVE: Currently, no quantitative and objective method has been established for evaluating competencies in basic surgical techniques. The aim of this study was to develop a structured assessment tool for slip knotting and verify how well current board certification system discriminates the level of basic surgical skill. METHODS: We examined 171 cardiovascular surgical fellows using a novel assessment method for slip knotting that was developed by the committee of the Under-Forty of the Japanese Society of Cardiovascular Surgery. We compared the scores and examinees' surgical experience for validation. We analyzed the relationship between board certification and the scores. RESULTS: The scores differentiated the general surgical board-certified surgeons from those without certification. Surgical experiences such as training years and number of operated cases and scores were correlated. Among the board-certified surgeons, the group with daily off-the-job training, or simulator-based skill training had a significantly higher mean score (67.4 ± 3.0 vs 55.4 ± 3.1, p = 0.008) and lower rate of poor scorers (7.1% vs 38.5%, p = 0.004). A multivariate analysis revealed that board certification did not predict high scores. Daily off-the-job training was the only independent predictor of high scores (odds ratio: 2.41, 95% confidence interval: 0.01-1.20, p = 0.014). CONCLUSIONS: This novel quantitative and objective assessment tool for technical skill in slip knotting was found to be valid to examine the skill for slip knotting. In this study, current board certification discriminated the level of basic surgical skill. However, it could not distinguish extremely low scorers perfectly. Some board-certified surgeons showed poor technical competency, especially those without off-the-job training.


Assuntos
Competência Clínica , Cirurgia Geral/educação , Cirurgia Geral/normas , Técnicas de Sutura/educação , Técnicas de Sutura/normas , Adulto , Atitude do Pessoal de Saúde , Procedimentos Cirúrgicos Cardiovasculares , Certificação , Avaliação Educacional , Bolsas de Estudo , Feminino , Humanos , Masculino , Inquéritos e Questionários , Adulto Jovem
14.
Gen Thorac Cardiovasc Surg ; 68(3): 310, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31705456

RESUMO

The article "Novel quantitative and objective structured assessment of technical skill for slip knotting", written by.

15.
Cardiovasc Intervent Radiol ; 42(10): 1488-1493, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31363897

RESUMO

PURPOSE: We presented a new method of sac embolization using n-butyl-cyanoacrylate (NBCA) with balloon occlusion of the aorta (SEBOA) that can facilitate decreasing flow rate of the involved branches with the goal of type 2 endoleak resolution after endovascular aortic repair (EVAR). TECHNIQUE: This technique is demonstrated in six patients who required type 2 endoleak treatment including previous technical failure. A transarterial approach was performed in four patients and transabdominal direct puncture in two. Technical success was defined as complete embolization of both involved branches and sac on postoperative CT. Sacography under balloon occlusion of the aorta demonstrated decreased flow rate of the all involved branches in all patients. SEBOA was performed using 25 or 33% of NBCA diluted with lipiodol. Technical success was obtained in 3 of 6 patients, and one major complication was observed with adhesion of NBCA to the microcatheter resulting in foreign body retention. CONCLUSION: SEBOA may help solve the difficulty of type 2 endoleak treatment after EVAR as decreased flow rate of the involved branches under balloon occlusion of the aorta was achieved in all patients. However, protocols regarding concentration of NBCA or using other embolic materials are needed to improve the success rate.


Assuntos
Aneurisma Aórtico/terapia , Oclusão com Balão/métodos , Embolização Terapêutica/métodos , Endoleak/terapia , Procedimentos Endovasculares/métodos , Idoso , Aorta/diagnóstico por imagem , Aneurisma Aórtico/complicações , Aneurisma Aórtico/diagnóstico por imagem , Embucrilato/administração & dosagem , Endoleak/complicações , Endoleak/diagnóstico por imagem , Óleo Etiodado/administração & dosagem , Feminino , Humanos , Masculino , Tomografia Computadorizada por Raios X , Resultado do Tratamento
16.
Cardiovasc Intervent Radiol ; 42(10): 1483-1487, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31254039

RESUMO

BACKGROUND: Endovascular treatment of infrarenal abdominal aortic aneurysm (AAA) with proximal chronic aortic dissection is challenging as a false and true lumen at the level of the infra-renal neck does not allow a sufficient landing zone. We describe staged endovascular neck stabilization prior to standard endovascular aortic repair (EVAR) for AAA with chronic aortic dissection. TECHNIQUE: To create a stable proximal neck (PN) by closing entry tears, thereby resulting in total false lumen thrombosis (FLT) prior to standard EVAR. Case 1 false lumen fenestrations were present at the descending aorta, the right renal artery orifice and PN. After closing the entry tear by thoracic EVAR, an aortic cuff was placed in the true lumen of the PN and renal stenting for the right renal artery was performed. After 2 months, total FLT was achieved, and EVAR was performed. Case 2 false lumen fenestrations were present at the descending, super celiac aorta and PN. After closing the entry by TEVAR, aortic cuffs were placed at infrarenal aorta to close residual entries. After 1 month of achieving total FLT, EVAR was performed. Both cases had no type 1 endoleak during follow-up. CONCLUSION: The endovascular neck stabilization is a useful treatment option that facilitates standard EVAR for AAA in chronic aortic dissection.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Idoso , Aorta Abdominal/cirurgia , Doença Crônica , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
17.
Ann Vasc Dis ; 11(1): 91-95, 2018 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-29682113

RESUMO

Objective: We evaluated early and mid-term results of endovascular aortic repair (EVAR) using crossed-limb and non-crossed-limb techniques. Material and Methods: From December 2011 to October 2013, 37 patients (31 men; mean age 75.4 years) were treated with EVAR (crossed-limb, 21 and non-crossed-limb, 16). We compared technical success, maximum short-axis diameter of abdominal aortic aneurysm, iliac angulation, time for catheterization of the short contralateral limb gate of the main body (SCT), and complications between the groups. Results: The mean follow-up period was 810±230 days. The technical success rate was 100%. There was no significant difference between the groups in terms of mean short-axis diameter. Iliac angulation was significantly wider in the crossed-limb group (53.3±14.6 vs. 39.4±13.0, p=0.0049). There was no significant difference between the groups in terms of SCT. Limb occlusion occurred in two cases (one crossed-limb and one non-crossed-limb). There were no aneurysm-related deaths. Conclusion: There were no differences between the crossed-limb and non-crossed-limb techniques in terms of early and mid-term results of EVAR. A crossed-limb technique can be performed safely without prolonged SCT even in severely splayed iliac angulation cases.

18.
Ann Thorac Surg ; 105(5): 1392-1396, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29277670

RESUMO

BACKGROUND: This study aimed to analyze the influence of the timing of intervention from presentation of symptoms to thoracic endovascular aortic repair (TEVAR) and its relation to major complications. Data were collected from the Japan Adult Cardiovascular Surgery Database. METHODS: We retrospectively analyzed the data of 680 patients who underwent TEVAR for acute and subacute type B dissection between January 2008 and January 2013. RESULTS: Thoracic endovascular aortic repair for type B dissection was performed in 680 patients: 295 repairs were performed within 24 hours of presentation of symptoms (hyperacute); 97 between 24 hours and 14 days (acute); and 288 between 14 days and 6 weeks (subacute). Hyperacute patients more frequently had immediate life-threatening complications from type B dissection such as rupture or malperfusion than did acute or subacute patients (41.0% [121 of 295] versus 7.2% [7 of 97] versus 4.2% [12 of 288]; p < 0.001; and 17.3% [51 of 295] versus 8.3% [8 of 97] versus 5.6% [16 of 288]; p < 0.001, respectively). Operative mortality and severe complications including aortic dissection were more common among hyperacute patients (11.9% [35 of 295] versus 0% [0 of 97] versus 1.7% [5 of 288]; p < 0.001; and 32.5% [96 of 295] versus 10.3% [10 of 97] versus 8.3% [24 of 288]; p < 0.001, respectively) and did not differ significantly between acute and subacute patients (p = 0.191 and p = 0.553, respectively). CONCLUSIONS: Although TEVAR performed for aortic dissection within 24 hours of presentation of symptoms was associated with worse outcomes, TEVAR performed between 24 hours and 14 days, as compared with TEVAR between 14 days and 6 weeks, does not appear to increase the risk of perioperative complications.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Procedimentos Endovasculares/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Tempo para o Tratamento , Idoso , Idoso de 80 Anos ou mais , Dissecção Aórtica/mortalidade , Aneurisma da Aorta Torácica/mortalidade , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
19.
Bioorg Med Chem Lett ; 27(9): 1902-1906, 2017 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-28359792

RESUMO

2,2,2-Trifluoro-1-{4-[(4-fluorophenyl)amino]pyrimidin-5-yl}-1-[1-(methylsulfonyl)piperidin-4-yl]ethanol 1 was identified as a novel potent aldosterone synthase inhibitor. Despite large species differences, compound 1 inhibits both human and rodent CYP11B2 in a nano-molar range.


Assuntos
Compostos de Anilina/química , Compostos de Anilina/farmacologia , Citocromo P-450 CYP11B2/antagonistas & inibidores , Inibidores Enzimáticos/química , Inibidores Enzimáticos/farmacologia , Pirimidinas/química , Pirimidinas/farmacologia , Citocromo P-450 CYP11B2/metabolismo , Células HEK293 , Humanos
20.
Ann Vasc Dis ; 9(3): 232-234, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27738470

RESUMO

A woman in her 80s with an infrarenal aortic aneurysm was scheduled for endovascular aortic repair (EVAR). The aneurysm had a severely angulated neck (SAN), and the Zenith Flex device was selected. Completion angiography showed migration of the main body resulting in right renal artery stenosis. A Palmaz genesis was placed across the renal orifice. The patient had no renal dysfunction and was discharged 7 days after EVAR. If Zenith Flex devices are used for a SAN, it is necessary to consider not only the position of the renal artery but also the appropriate position of the stent-graft.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...